top of page
WhatsApp Image 2026-07-22 at 2.58.28 PM.jpeg
1.jpg.jpeg

AUTO-RECLOSER

Overhead Networks

AUTO-RECLOSER 

AUTO-RECLOSER

Overhead Networks

AUTO-RECLOSER

Overhead Networks

Sugs internal pages top banners-07.jpg

AUTO-RECLOSER (AR)
OVERHEAD NETWORKS

Reducing Outages with Automated Reclosing & Optimal Re-routing

Our Auto-Recloser detects transient & permanent  faults on overhead distribution lines and automatically reroutes & restores the power supply. This helps reduce avoidable outages, improve feeder reliability, and minimise manual intervention.

AR_4x.png

How It Works?

Icon shape_4x.png
Asset 6_4x.png
Asset 5_4x.png
Asset 4_4x.png
Asset 3_4x.png
Asset 4_4x.png
Asset 1_4x.png

Monitor

Current Sensor Tracks Line Current Continuously

Detect

Current Spikes Instantly When Fault Occurs

Trip

Circuit Opens to Interrupt Fault Current

Reclose

Automatic Attempt to Restore Service (1st, 2nd, 3rd cycle)

Clear

Permanent Fault Isolated, Transient Faults Cleared

Restore

Service Restored or Lockout Initiated

Solid Dielectric Auto-Recloser. It comes in 11KV & 33KV

Asset 2_4x.png

Applications

leaf icon (1).png

Medium Voltage (MV) overhead feeders

leaf icon (1).png

Urban and rural distribution networks

leaf icon (1).png

Smart grid and distribution automation systems

Features

AR_AR.jpg

Automatic fault detection and instantaneous response

AR_AR copy.jpg

Intelligent trip and reclose cycles (typically 3-5 attempts)

AR_AR copy 2.jpg

Phase-to-phase and phase-to-earth fault identification capability

Asset 59_4x.png

Automatic fault clearing without manual intervention

AR_AR copy 4.jpg

SCADA compatible with IEC 60870-5-104 protocol & MQTT

Asset 58_4x.png

SMS reportingof events

FPI Icons_FPI-11.jpg

24/7 operation with real-time fault monitoring

Asset 61_4x.png

Coordinated operation with downstream protection

Specification
Value
Significance
Operating Voltage Levels
11 kV, 22 kV, 33 kV
Covers all distribution levels in India
Fault Detection Speed
<200 milliseconds
Faster than manual intervention
Fault Current Range
5A to 2000A
Detects all fault magnitudes
Trip-Reclose Cycles
3-5 attempts
Clears transient faults automatically
Reclose Delay
Configurable (0.5-3 sec)
Allows fault deionization time
Operating Temperature
-20°C to +60°C
Works in extreme Indian climate conditions
Water/Dust Protection
IP54-IP55 Rating
Monsoon-proof, weather-resistant
Installation Method
Pole-mounted or ground-mounted
Flexible deployment options
Power Supply
AC from line or battery backup
24/7 operation capability
Communication Range
RF: 2-5km, 4G: Nationwide
SCADA integration available
SCADA integration available
10,000+ operating cycles
Long-term reliability
AR_4x (1).png

USPs & Key Benefits

leaf icon (1).png

Automatic fault clearing without manual intervention

leaf icon (1).png

Improved SAIDI and SAIFI metrics

leaf icon (1).png

Scalable solution for smart grid initiatives

leaf icon (1).png

Reduced customer interruptions (transient faults cleared)

leaf icon (1).png

Prevents unnecessary crew dispatch

leaf icon (1).png

Selective isolation capability

leaf icon (1).png

Faster restoration time for permanent faults

leaf icon (1).png

Coordinated operation with downstream protection

Know more about
Fault Passage Indicators!

Fault Passage Indicators enable real-time fault detection, faster fault isolation, and reduced downtime across power distribution networks.

bottom of page